Enhance Daylighting of Staff Room in Faculty of Architecture, Urban Design and Creative Arts, Mahasarakham University
DOI:
https://doi.org/10.14456/bei.2019.4Keywords:
Daylight, Daylight simulation, Energy conservation, Green building, DialuxAbstract
This research aims to find the best daylight enhancing lighting model, according to the Illuminating Engineering Association of Thailand’s guideline (not less than 300 lux), for staff room renovation in Faculty of Architecture, Urban Design and Creative Arts Mahasarakham University.
The study was conducted through daylight simulation models performing under various room conditions according to the renovation plan then data was analyzed through the illuminance indicators from a DIALux program. The result reveals that the best lighting renovation model is a ceiling and partition adjustment model which has 123.70% of an annual average illuminance rate while before the renovation under the clear sky with direct sunlight condition and decreased to 121.91% under the overcast sky condition. On the illuminance uniformity indicator (not less than 0.6), before renovating the room has 0.401 under the clear sky with direct sunlight condition and decreased to 0.332 under the overcast sky condition. The model is proved to be effective in enhancing the daylighting of the room under a clear sky with direct sunlight condition since if cans increased the illuminance to 750 lux. On the other hand, under the overcast sky condition the model can only offer 300 lux of illuminance which means the lighting must be added under the case.
References
DIALux light building software. (2016). DIALux 4 with new improved calculation kernel. Retrieved from http://dialux4.support-en.dial.de/helpdesk/attachments/ 9005537029
Egan, M.D., & Olgyay, V. (2002). Architectural lighting (2nd ed). New York, NY: McGraw-Hill.
Faculty of Architecture, Urban Design and Creative Arts, Mahasarakham University. (2016).yutthasāt. (In Thai) [Strategic]. Retrieved from http://arch.msu.ac.th/ยุทธศาสตร์
Illuminating Engineering Association of Thailand. (2003). TIEA - GD sām khō̜ nænam radap khwām sō̜ng sawāng phāinai ʻākhān khō̜ng prathēt Thai. (In Thai) [TIEA-GD003 Recommendation of the level of indoor illumination in Thailand]. Bangkok: The Association.
Muttisa, C. (2005). patčhai kāiyaphāp hing sathō̜n sǣng thı̄ mı̄ phon tō̜ kānnam sǣng thammachāt khao mā chai nai ʻākhān. (In Thai) [The impacts of lightshelf’s physical factors on daylighting in buildings] (Unpublished master’s thesis). Chulalongkorn
University, Bangkok, Thailand.
Oakley, G., Riffat, S.B., & Shao, L. (2000). Daylight performance of lightpipes. Solar Energy, (69), 89-98.
Tawanyim. (2014). thammai ? ? ? ʻākhān samai mai tō̜ng pen Green building. (In Thai) [Why ??? modern buildings must be green building]. Green Network a Magazine for People Who Love the World, (49), 18-19.
UI GreenMetric. (2016). Overall ranking 2016. Retrieved from http://greenmetric. ui.ac.id/overallranking-2016
Downloads
Published
How to Cite
Issue
Section
License
Views and opinions expressed in the journal do not necessarily reflect those of the editors.